Mechanical Monitoring Tool

Vibration Severity Rating (ISO 10816)

Classify vibration severity for industrial machines using ISO 10816-3: the international standard for evaluating machine vibration measured on non-rotating parts.

Key Insight

A vibration reading by itself means little. What matters is where it falls relative to the machine's baseline and what ISO 10816 says about machines of that class. This tool converts a measured velocity value into an actionable zone classification.

Vibration Zone Classifier

Select based on rated power output and shaft height
Enter RMS velocity in mm/s
Please enter a valid positive number and select a machine group.
Where your reading falls on the ISO 10816-3 scale

How ISO 10816 Classifies Machine Vibration

Vibration velocity RMS (root mean square) is the primary measurement parameter in ISO 10816-3 for assessing overall machine health on non-rotating parts. Velocity, expressed in millimeters per second or inches per second, is particularly sensitive to the frequency ranges most associated with mechanical faults in industrial rotating equipment: imbalance, misalignment, looseness, and bearing degradation. Unlike displacement (which emphasizes low-frequency motion) or acceleration (which is more sensitive to high-frequency events), velocity provides a balanced view across the mid-frequency range most relevant to structural damage risk.

ISO 10816-3 groups machines by rated power and shaft height, because the same absolute vibration level represents different risk depending on machine mass, rigidity, and operating speed. A 2.5 mm/s reading on a large 500 kW compressor may be unremarkable; the same reading on a 30 kW pump motor would place it in Zone B, warranting increased monitoring. The standard defines four zones, A through D, each corresponding to a different operational status and recommended response.

Zone A covers vibration typical of newly commissioned equipment operating within design tolerances. Zone B represents levels acceptable for continuous long-term operation in most installations, though any upward trend warrants investigation. Zone C indicates vibration that, while not immediately catastrophic, is not suitable for sustained operation and points to an underlying fault requiring correction. Zone D signals vibration severe enough to risk sudden failure or damage to the machine or connected equipment, and the standard recommends considering shutdown pending an engineering assessment.

The standard specifies that measurements should be taken on bearing housings and structural parts of the machine: non-rotating surfaces where vibration energy transmits from the rotating assembly into the structure. This placement makes readings comparable across machines and consistent with the zone boundary values defined in the standard. Measurements taken elsewhere, such as on pipe flanges, frames, or machine bases, may not correlate reliably to the ISO 10816-3 thresholds.


ISO 10816-3 Zone Boundary Reference

Zone boundaries in mm/s and in/s (1 mm/s = 0.03937 in/s). Applies to machines with nominal power above 15 kW and speeds between 120 and 15,000 rpm, measured in situ on non-rotating parts.

Zone Description Group 1 (mm/s) Group 1 (in/s) Group 2 (mm/s) Group 2 (in/s)
A Newly commissioned ≤2.3 ≤0.091 ≤1.4 ≤0.055
B Acceptable for continuous operation 2.3 – 4.5 0.091 – 0.177 1.4 – 2.8 0.055 – 0.110
C Not suitable for long-term operation 4.5 – 7.1 0.177 – 0.280 2.8 – 4.5 0.110 – 0.177
D Danger: damage risk >7.1 >0.280 >4.5 >0.177

Group 1: Large machines with rated power above 300 kW or shaft centreline height above 315 mm. Examples: large centrifugal pumps, reciprocating compressors, steam turbines, large fans.

Group 2: Medium machines with rated power between 15 kW and 300 kW. Examples: standard industrial induction motors, centrifugal pumps, HVAC fans, gearbox-driven equipment.


Where and How to Take Measurements

ISO 10816-3 specifies that measurements are taken on the bearing housings of the machine under assessment, not on the rotor or shaft. The bearing housing transmits the mechanical forces generated by the rotating assembly and provides a consistent, accessible measurement point across machine types.

For each bearing location, measurements should be taken in three orthogonal directions:

The highest reading across all measurement directions at a given bearing is typically used for zone classification. For most rotating machines, the radial readings (horizontal and vertical) are higher than axial, with axial becoming more significant in cases of misalignment or thrust bearing issues.

Measurements should be taken with the machine at normal operating load and temperature, not during startup or coast-down. Temporary transient vibration during those phases does not reflect the steady-state condition the standard is designed to evaluate. Use a calibrated vibration meter or data collector with flat frequency response from at least 10 Hz to 1,000 Hz for overall velocity RMS measurements.


Unit Conversion Reference

1 mm/s = 0.03937 in/s
1 in/s = 25.4 mm/s

RMS velocity (mm/s) = Peak velocity / √2 [for sinusoidal signals]
RMS velocity (mm/s) = √( (1/T) × ∫ v(t)² dt ) [true RMS definition]

Most modern vibration instruments report true RMS velocity directly. For instruments that report peak velocity, divide by √2 (1.414) to convert to RMS. This conversion applies exactly only to pure sinusoidal signals. For complex waveforms typical of real machines, use the instrument's true RMS output.

Standard Reference Source: ISO 10816-3:2009, Mechanical vibration: Evaluation of machine vibration by measurements on non-rotating parts: Part 3: Industrial machines with nominal power above 15 kW and nominal speeds between 120 r/min and 15,000 r/min when measured in situ. Note: ISO 20816-3:2022 supersedes ISO 10816-3 with updated machine categories; consult the current standard for new installations.
Measurement Conditions and Applicability Zone classifications assume measurements taken per ISO 10816 procedure on bearing housings in the radial direction. Measurements on machine casings, frames, or other locations may not be comparable. This tool uses ISO 10816-3 (2009). Verify which version of the standard applies to your installation. Zone boundaries are guides: machine-specific alarm levels from the OEM always take precedence.
Tools on this site are provided for educational purposes only. Calculations are based on published engineering formulas and industry standards cited on each tool. Results do not constitute professional engineering advice. Do not make maintenance, safety, or operational decisions based solely on these outputs. Always verify results against your equipment manufacturer's documentation and consult a qualified engineer or reliability professional before acting. This site accepts no liability for decisions made using these tools.