Each fault type occupies a predictable location in the vibration spectrum. An imbalanced rotor appears at exactly 1x shaft speed. A bearing with an outer race defect appears at BPFO, a known multiple of shaft speed calculated from the bearing geometry. Knowing the expected frequency is the first step in finding the fault.
Shaft Speed Reference
Everything in rotating machinery vibration is referenced to shaft speed. Shaft frequency is the fundamental unit from which all other fault frequencies are derived.
Fault frequencies are expressed in two ways: as orders (multiples of shaft frequency, such as 1x, 2x, 3x) or as absolute frequencies calculated from shaft speed and component geometry. Orders scale with machine speed; absolute frequencies require a calculation using the current shaft speed.
When analyzing a spectrum, always establish shaft speed first. Confirm it against the tachometer reading and verify the 1x peak location before interpreting any other spectral content. All subsequent fault frequencies are anchored to that reference.
Imbalance
Primary frequency: 1x shaft speed, dominant in the radial direction.
Imbalance produces a single, clean peak at exactly shaft frequency. The force generated by an out-of-balance rotor is described by:
Because force is proportional to the square of angular velocity, imbalance severity grows rapidly with speed. A rotor that produces acceptable vibration at 1,500 RPM can become problematic at 3,000 RPM with the same unbalance magnitude.
Confirming features:
- The axial component at 1x is small. If the axial reading at 1x is significant, misalignment is also present.
- Phase angle at 1x is stable across repeated measurements on the same machine in the same operating condition.
- Amplitude changes predictably when speed changes (increases with speed squared).
- Correction is by field balancing: adding or removing mass at specific angular positions to move the center of mass toward the axis of rotation.
Angular Misalignment
Primary frequency: 2x shaft speed, dominant in the axial direction.
Angular misalignment occurs when two shaft centerlines meet at an angle rather than running parallel and collinear. The coupling must flex through that angle with every revolution, generating a force pulse twice per revolution (once on each side of rotation).
Confirming features:
- Strong axial vibration at 1x and 2x. The axial reading at 1x distinguishes angular misalignment from pure imbalance, which shows very little axial content.
- 180-degree phase difference between the inboard and outboard bearings when measured axially at 2x. This is the most reliable confirmation.
- 2x amplitude in the axial direction typically exceeds 2x amplitude in the radial direction.
- Coupling runs warm due to repeated angular deflection.
Parallel (Offset) Misalignment
Primary frequency: 2x shaft speed, radial direction. The 1x and 2x peaks are often similar in amplitude.
Parallel misalignment occurs when two shaft centerlines are parallel but offset laterally. The coupling compensates for this offset with each revolution, producing a two-per-revolution radial force. Unlike angular misalignment, the axial component is not the dominant indicator.
Confirming features:
- 1x and 2x amplitudes are comparable in the radial direction. When 2x approaches or equals 1x radially, parallel misalignment is the likely cause.
- 180-degree phase difference between inboard and outboard bearings at 2x, measured radially.
- Coupling generates heat from repeated lateral deflection.
- In practice, angular and parallel misalignment often coexist. The combined signature shows elevated 1x and 2x in both radial and axial directions.
Bearing Outer Race Defect (BPFO)
Primary frequency: BPFO (Ball Pass Frequency, Outer Race). The outer race is stationary, so each rolling element strikes the defect at a fixed, predictable frequency.
BPFO is sub-synchronous for most standard bearings, meaning it falls below 1x shaft speed. Typical values range from 0.4x to 0.6x of N times shaft frequency, depending on bearing geometry. The exact value must be calculated from the bearing's dimensional data.
Confirming features, by fault stage:
- Early stage: No sidebands. The BPFO peak appears in the spectrum but at low amplitude. High-frequency resonance excitation is often the first detectable indicator, visible in the acceleration envelope (demodulated) spectrum centered on bearing natural frequencies (typically 2,000 to 20,000 Hz).
- Developing stage: Sidebands appear at BPFO ± 1x shaft frequency. The sideband spacing of exactly 1x confirms the BPFO identification.
- Advanced stage: Sideband amplitude grows as the defect area enlarges. Multiple harmonics of BPFO become visible. The noise floor rises.
The outer race fault produces a consistent impact with each rolling element pass because the defect is stationary in the load zone. This is why BPFO sidebands are at shaft frequency rather than showing load-zone amplitude modulation (which is the distinguishing feature of inner race faults).
Bearing Inner Race Defect (BPFI)
Primary frequency: BPFI (Ball Pass Frequency, Inner Race). The inner race rotates with the shaft, so the defect passes through the load zone once per shaft revolution.
BPFI is always higher than BPFO for the same bearing at the same speed. BPFI is super-synchronous relative to individual element pass rates.
Confirming features:
- Sidebands at BPFI ± 1x shaft frequency are always present, even in early fault stages. This is because the defect rotates with the shaft and the impact amplitude varies as the defect moves through the load zone and out of it.
- The amplitude modulation at 1x shaft frequency is the key distinguishing feature separating inner race faults from outer race faults. Outer race faults show sidebands that grow with damage; inner race faults always show sidebands because of load-zone modulation.
- Detectable in acceleration envelope spectrum at the same high-frequency resonance bands used for outer race detection.
- Phase of the sidebands shifts as the defect progresses; sideband amplitude grows relative to BPFI amplitude as the fault develops.
Rolling Element (Ball) Defect: BSF
Primary frequency: BSF (Ball Spin Frequency), sometimes called BSF or roller defect frequency. A defect on the ball contacts alternating inner and outer races with each spin revolution.
BSF is sub-synchronous, typically between 0.4x and 0.5x shaft speed. The 2x BSF harmonic is also common because the defect strikes both the inner and outer race within one full ball revolution.
Confirming features:
- Ball defects are the most difficult common bearing fault to detect. Because the defect alternates contact surfaces, the excitation pattern is less consistent than race defects and can appear random in the time waveform.
- BSF and 2x BSF appear in the low-frequency spectrum but at relatively low amplitude compared to race defect peaks at equivalent fault severity.
- The most reliable detection is in the high-frequency acceleration envelope spectrum. A defective ball generates high-frequency shock pulses that are captured by envelope demodulation even when the low-frequency BSF peak is buried in noise.
- FTF (cage frequency) may also appear as a modulation frequency if the cage is also affected.
Cage Defect: FTF
Primary frequency: FTF (Fundamental Train Frequency), also called cage frequency. The cage rotates at a fraction of shaft speed.
FTF is always sub-synchronous, typically between 0.3x and 0.45x shaft speed. It is the lowest-frequency bearing defect frequency.
Confirming features:
- FTF appears in the very low-frequency portion of the spectrum. It can be obscured by low-frequency noise and requires a spectrum with sufficient resolution at low frequencies to detect reliably.
- FTF often appears as a modulation frequency on BPFO and BPFI peaks, producing sidebands spaced at FTF intervals around the race defect frequencies. This is a more common detection route than a standalone FTF peak.
- Cage damage typically occurs alongside rolling element or race damage rather than as an isolated fault. A standalone FTF peak with no race defect peaks suggests early cage wear or lubrication starvation.
- Acceleration envelope analysis at high frequencies is effective for cage fault detection, where cage irregularity produces irregular spacing in the impact pattern.
Gear Mesh Frequency
Primary frequency: GMF (Gear Mesh Frequency). Every tooth on the driving gear engages a tooth on the driven gear; the engagement rate is the shaft speed multiplied by the number of teeth.
GMF is typically well above shaft speed for any practical gear set. A 40-tooth gear running at 1,500 RPM produces a GMF of 1,000 Hz.
Confirming features:
- Amplitude at GMF and its harmonics (2x GMF, 3x GMF) indicates the overall transmission error of the gear set. Harmonics are always present to some degree; the amplitude distribution across harmonics reflects tooth profile quality.
- Sidebands at GMF ± shaft frequency identify which shaft carries the localized defect. Sidebands spaced at the pinion shaft frequency point to a pinion tooth defect; sidebands at gear shaft frequency point to a gear tooth defect.
- Sideband amplitude relative to the GMF amplitude is a gear health indicator. Healthy gears have low sideband amplitude. Sideband growth relative to GMF indicates developing tooth damage.
- Ghost frequencies (spectral lines at non-integer multiples of shaft speed near GMF) can indicate manufacturing errors in the tooth count or pitch rather than in-service damage.
- Time waveform analysis is useful for gear faults: a damaged tooth produces a periodic impact once per revolution of the shaft carrying it.
Mechanical Looseness
Primary frequency: Integer multiples of shaft speed: 1x, 2x, 3x, 4x, 5x and higher. Sub-harmonics at 0.5x, 1.5x, 2.5x may also be present.
Mechanical looseness occurs when a component (bearing housing, base, coupling) is not properly secured. The loose element impacts adjacent structure once or multiple times per shaft revolution, generating a rich harmonic series.
Confirming features:
- A spectrum with many harmonics of shaft speed that extends well above what imbalance or misalignment would produce (which typically shows only 1x and 2x). Five or more harmonics visible at meaningful amplitude is a strong looseness indicator.
- Sub-harmonics at 0.5x and 1.5x indicate looseness severe enough to produce impacts at non-integer fractions of shaft speed. This occurs when the loose element bounces in a pattern that is not synchronized to every revolution.
- The noise floor rises as looseness becomes severe. Random noise increases because impacts excite a wide frequency range.
- Time waveform shows clipping or truncation in severe cases, where the signal is bounded by a structural constraint (the limit of clearance in the loose joint).
- Phase is unstable across repeated measurements. Because the contact pattern changes slightly between measurements, the phase at each harmonic shifts. This instability is diagnostic: imbalance and misalignment have stable phase.
- Looseness at the bearing housing produces different harmonic patterns than looseness at the base or at the coupling. The location of maximum amplitude (inboard vs. outboard bearing, radial vs. axial) narrows the probable source.
Resonance
Resonance occurs when a forcing frequency coincides with a structural natural frequency. At resonance, the vibration amplitude is amplified by the Q factor (quality factor) of the structure. Q factors for typical industrial structures range from 5 to 50, meaning vibration at resonance can be 5 to 50 times the amplitude it would be at a non-resonant frequency.
Primary signature: Abnormally high amplitude at a frequency that corresponds to both a forcing frequency (1x, 2x, GMF, etc.) and a structural natural frequency. The high amplitude alone does not confirm resonance; the frequency must match a natural frequency of the structure.
Confirming features:
- Amplitude changes significantly with small speed changes through the resonant speed. An amplitude that doubles or triples with a 5% speed change indicates a resonance at that speed.
- A bump test (impact hammer test) confirms structural natural frequencies independently of the running machine. If a natural frequency identified by bump test matches the high-amplitude running frequency, resonance is confirmed.
- The phase angle at the resonant frequency shifts by approximately 90 degrees at resonance and by up to 180 degrees as the forcing frequency passes through the natural frequency.
- Resonance can amplify any forcing frequency: 1x (imbalance-driven), 2x (misalignment-driven), GMF (gear-driven), or bearing defect frequencies. The fault producing the forcing frequency still needs to be addressed, but the structural resonance is a separate problem that multiplies its effect.
Correction options:
- Change operating speed to move the forcing frequency away from the natural frequency.
- Add mass to lower the natural frequency, or stiffen the structure to raise it.
- Add damping (constrained-layer damping, tuned mass dampers) to reduce the Q factor and the amplification at resonance.
Comprehensive Fault Frequency Reference
| Fault | Primary Frequency | Typical Direction | Confirming Features | Common Detection Tools |
|---|---|---|---|---|
| Imbalance | 1x shaft speed | Radial (dominant); axial small | Stable phase at 1x; amplitude scales with speed squared; clean single peak | Velocity spectrum; phase measurement; field balancing equipment |
| Angular misalignment | 1x and 2x shaft speed | Axial (dominant at 2x) | Strong axial 1x and 2x; 180-degree phase difference inboard vs. outboard axially at 2x | Velocity spectrum; phase measurement; laser alignment tool |
| Parallel misalignment | 2x shaft speed (radial) | Radial (dominant) | 1x and 2x comparable amplitude radially; 180-degree phase inboard vs. outboard radially | Velocity spectrum; phase measurement; laser alignment tool |
| Bearing outer race (BPFO) | BPFO = (N/2) × f × (1 - (d/D) cosθ) | Radial | Sidebands at BPFO ± 1x; no load-zone modulation; high-frequency envelope impacting | Acceleration envelope (demodulation); high-frequency spectrum; bearing calculation tables |
| Bearing inner race (BPFI) | BPFI = (N/2) × f × (1 + (d/D) cosθ) | Radial | Sidebands at BPFI ± 1x always present (load-zone modulation); amplitude modulated at 1x | Acceleration envelope; high-frequency spectrum; bearing calculation tables |
| Rolling element defect (BSF) | BSF = (D/2d) × f × (1 - ((d/D) cosθ)²); typically 0.4x to 0.5x shaft speed | Radial | BSF and 2x BSF; irregular impact pattern; best detected in high-frequency envelope | Acceleration envelope; kurtosis analysis; high-frequency spectrum |
| Cage defect (FTF) | FTF = (f/2) × (1 - (d/D) cosθ); typically 0.3x to 0.45x shaft speed | Radial (low frequency) | Very low frequency; appears as modulation on BPFO and BPFI peaks; irregular impact spacing | Low-frequency spectrum; acceleration envelope; time waveform pattern analysis |
| Gear mesh (GMF) | GMF = teeth × (RPM/60); harmonics at 2x, 3x GMF | Radial and axial | Sidebands at GMF ± shaft frequency identify defect location; sideband-to-GMF ratio tracks severity | High-frequency velocity spectrum; time waveform; cepstrum analysis |
| Mechanical looseness | Multiple integer harmonics of shaft speed (1x, 2x, 3x...); sub-harmonics 0.5x, 1.5x | Radial or axial depending on loose joint orientation | Rich harmonic series; unstable phase; elevated noise floor; time waveform clipping | Velocity spectrum; phase measurement; time waveform; inspection |
| Resonance | At a forcing frequency that coincides with a structural natural frequency | Any, depending on mode shape | Amplitude highly sensitive to small speed changes; confirmed by bump test; phase shifts 90 to 180 degrees at resonance speed | Bump test (impact hammer); operating deflection shapes; speed sweep (coast-down/run-up) |
Continuous Fault Frequency Monitoring
Tractian's monitoring computes fault frequencies from machine nameplate data and trends amplitude at each location continuously, alerting when specific fault signatures exceed thresholds.
See Mechanical Monitoring