A compressed air leak the size of a 1mm hole at 7 bar costs approximately 1,400 kWh of compressor energy per year. Ultrasound surveys find these leaks in minutes during normal plant operation, without shutting down equipment or isolating systems.
Bearing Condition with Ultrasound
Ultrasound detects bearing degradation through friction and impact sounds generated at 20 kHz to 100 kHz. These frequencies arise when the lubrication film is inadequate or when surface defects contact the opposing race. They are inaudible to the human ear and largely invisible in standard vibration velocity spectra, which is what makes ultrasound effective as an early-warning complement to vibration analysis.
The measurement procedure is straightforward: place a contact probe on the bearing housing at the same marked location each time, record the reading in dBµV, and compare against the baseline established when the bearing was in confirmed good condition.
The +8/+16 dBµV alarm convention
The decibel scale is logarithmic. A change of 8 dBµV represents a roughly 2.5-fold increase in signal amplitude; 16 dBµV represents approximately a 6-fold increase. These thresholds have become the industry standard for two-level alerting:
- +8 dBµV above baseline: first alarm. Increase inspection frequency. Verify lubrication adequacy. Collect vibration spectrum for corroboration.
- +16 dBµV above baseline: danger alarm. Plan replacement at next available window. Increase monitoring to weekly or continuous if run-to-failure risk is high.
Audio character as diagnostic information
Ultrasound instruments convert the high-frequency signal to audible range through heterodyne processing. The sound character provides diagnostic context that the dBµV number alone does not:
- Smooth, quiet hiss: healthy bearing with adequate lubrication.
- Elevated hiss, elevated amplitude: friction due to insufficient lubrication. The bearing surface condition may still be intact.
- Grinding or clicking: surface defects in contact. Stage 2 to Stage 3 bearing damage.
- Rumbling or irregular impacts: advanced damage. Spalling is distributed. Plan immediate replacement.
Lubrication Guidance with Ultrasound
Ultrasound provides real-time feedback during the relubrication process. This is its most operationally valuable application for many maintenance teams, because it converts an imprecise task (how much grease does this bearing need?) into a controlled, measurable one.
The relubrication procedure
- Take an ultrasound reading before adding any grease. Record the amplitude in dBµV. This is your starting point for this service event.
- Add grease slowly, in small increments. Pause between additions.
- Monitor amplitude continuously while adding grease. A properly lubricated bearing will show amplitude declining toward the normal baseline as the oil film rebuilds.
- Stop adding grease when amplitude returns to the normal baseline range, or when new grease appears at the relief fitting, whichever comes first.
The three characteristic amplitude responses
| Condition | Amplitude response to added grease | Audio character |
|---|---|---|
| Under-lubricated | Elevated above baseline; declines as grease is added | Friction hiss; quiets with grease addition |
| Correctly lubricated | At or near baseline | Smooth, quiet |
| Over-lubricated | Rises sharply; bearing becomes noisy and hot; settles as excess expels | Turbulent rushing sound; may trigger heat alarm on motor |
Over-lubrication is a genuine failure mode. Packed grease churns against the rolling elements, generating heat that degrades the lubricant and accelerates the bearing damage it was meant to prevent. Ultrasound feedback stops the technician before the bearing is overpacked.
Compressed Air Leak Detection
Turbulent flow through any orifice generates broadband ultrasound. A leak in a pressurized compressed air system produces a distinct high-frequency signature that separates from the background noise of operating machinery.
The procedure requires no system shutdown, no isolation, and no specialized environmental conditions. Scans run during normal plant operation.
Survey procedure
- Use an airborne receiver with a parabolic dish or focused probe. The focused probe is better for identifying exact leak locations in congested piping; the parabolic dish is better for scanning across larger distances.
- The detector converts the 40 kHz ultrasound signal to audible range. The operator hears the leak as a hiss or rushing sound through headphones.
- Scan systematically along compressed air lines, fittings, unions, quick-connect couplings, valve stems, regulator bodies, and filter bowls.
- When a signal is detected, move the probe to maximize the signal strength. The direction of maximum signal identifies the leak source.
- Tag the leak location with a numbered tag. Record: tag number, location description, estimated severity (based on signal strength), date found.
Estimating leak cost
Once a leak is tagged, its energy cost can be estimated from the orifice size, system pressure, and local electricity rate. A rough rule: a 1mm diameter hole at 7 bar consumes approximately 1,400 kWh per year of compressor energy. A 3mm hole at the same pressure consumes roughly 12,500 kWh per year. Documenting estimated costs per leak creates a prioritized repair list that justifies the survey investment.
Gas and Steam Leak Detection
The same turbulent flow principle applies to natural gas, process gases, and steam. The survey approach is similar; the hazard context differs and requires additional precautions.
Natural gas
Use an ultrasound detector rated for the environment. Ultrasound detection locates the source by signal strength, but it cannot distinguish gas species. Confirm any located signal with a calibrated gas detector before labeling the location as a leak and before approaching for close inspection. Tag the confirmed location and defer repair to qualified personnel following the applicable lockout procedure.
Steam
Steam leaks from trap bodies, valve packing, and flanged joints are detectable with the system under pressure. Working near steam surfaces requires thermal PPE. Steam trap assessment by ultrasound is a specific application with defined diagnostic criteria:
- Functioning trap (intermittent discharge type): produces an intermittent flow sound as condensate is discharged and the trap reseats. Intervals vary by trap type and load.
- Failed-open trap: continuous flow sound. Live steam passing through to the condensate return. The trap is no longer performing its function.
- Blocked trap: silent or near-silent. Condensate is backing up into the steam space. This reduces heat transfer efficiency and can cause water hammer.
Log the sound character for each trap on the survey route. Compare to the expected pattern for that trap type and the previous survey record. A trap that was intermittent on the last survey and is now continuous has failed open since that date.
Electrical Discharge Detection
Partial discharge, corona, tracking, and arcing in electrical equipment produce acoustic emission at frequencies detectable by airborne ultrasound through panel ventilation openings, without opening energized equipment.
The characteristic audio patterns:
- Corona: steady hiss at a consistent amplitude. Indicates high electric field gradient at a conductor surface or insulation edge. Common in high-voltage switchgear with contaminated insulators.
- Tracking: crackling sound, often intermittent. Indicates a conductive path forming across an insulation surface.
- Arcing: irregular high-amplitude bursts. The most urgent finding. Indicates active discharge between conductors or between a conductor and ground.
Ultrasound electrical surveys do not replace infrared thermography or partial discharge testing. They provide a non-invasive screening method that can be performed as part of an integrated electrical panel inspection route, allowing thermal and acoustic data to be collected in the same pass.
Survey Route and Documentation
A single ultrasound reading has limited diagnostic value. The value is in the trend: what has changed since the last reading, at the same point, under the same conditions.
Bearing route discipline
- Mark each measurement point with paint or a permanent sticker. The probe placement must be consistent to within a few millimeters; small position changes affect the reading.
- Use the same contact pressure each time. Most instruments have a force indicator or use a fixed-force probe adapter for route work.
- Use the same frequency setting (typically 38-40 kHz for bearing routes).
- Record: measurement point ID, dBµV reading, audio character description, date, technician.
Leak survey route discipline
- Define a fixed scan path that covers each distribution leg from the compressor room outward. Scan the full path each survey, not just suspect areas.
- Log each finding with a tag number, GPS coordinates or floor plan reference, pressure zone, estimated orifice size category (small, medium, large based on signal strength), and estimated annual cost.
- Compare each survey to the previous one. New signal locations that did not appear in the prior survey identify leaks that developed in the interval between surveys.
A documented leak survey repeated at six-month intervals creates a measurable metric: total estimated leak energy loss per period, and the reduction achieved by completing the repair list from each survey. This is the evidence that justifies continued investment in the program.