An IR camera gives you a temperature map of every surface in the field of view. A bearing running 25 C above its symmetrical pair on the same shaft is worth investigating. A coupling running hotter than both adjacent bearings points to misalignment. Thermography finds these patterns in seconds, without contact.
How Infrared Thermography Works
All objects above absolute zero emit thermal radiation. The intensity and wavelength distribution of this radiation depends on the object's temperature and its emissivity. Infrared cameras detect this radiation in the 3-5 µm or 8-14 µm wavelength range and convert it to a temperature map using the Stefan-Boltzmann law. The camera displays a false-color thermal image where each pixel represents a temperature value.
The 8-14 µm band (longwave infrared) is the more common choice for industrial mechanical surveys. It covers the peak emission wavelengths for objects at typical industrial temperatures (0-500 C) and is less susceptible to atmospheric interference over short inspection distances. The 3-5 µm band (midwave infrared) is used for applications involving very high temperatures or specific research requirements.
Modern IR cameras express this as a thermal image with a superimposed color palette. The palette choice (rainbow, iron, greyscale) does not change the underlying temperature data; it only changes how the analyst perceives contrast. For fault detection work, high-contrast palettes that emphasize small temperature differences are more useful than broad-range displays that compress the scale.
Emissivity: The Critical Variable
Emissivity is the ratio of a surface's actual thermal emission to that of a perfect blackbody radiator at the same temperature. It ranges from 0 to 1: a blackbody has emissivity = 1; polished aluminum has emissivity around 0.05; painted steel is typically 0.85-0.95; human skin is approximately 0.98.
Getting emissivity wrong produces incorrect temperature readings. A polished bearing housing set to emissivity 1.0 will appear significantly cooler than actual because the camera interprets the low thermal emission as low temperature, not as high reflectivity. A shiny stainless surface can easily read 30-50 C lower than its true temperature if emissivity is uncorrected.
Two practical correction methods:
- Contact thermometer reference: Measure the surface temperature with a calibrated contact probe, then adjust the IR camera's emissivity setting until both readings agree. This gives you the correct emissivity value for that surface finish and material combination.
- Reference tape: Apply masking tape (emissivity approximately 0.95) to a small area of the surface and use that patch as the measurement reference. The tape equilibrates to the surface temperature within a few minutes and gives a reliable reading even on polished metal.
Emissivity also varies with surface condition, angle of view, and temperature. For consistent survey-to-survey comparison, photograph from the same angle and record the emissivity setting used. Surfaces that have been cleaned, painted, or oxidized between surveys may require a new emissivity measurement.
Applications in Mechanical Condition Monitoring
Thermography applies across most rotating and static mechanical equipment. The following table lists the most common mechanical applications, the fault mode detected, and the expected temperature indicator.
| Application | What Thermography Detects | Temperature Indicator |
|---|---|---|
| Bearing housing | Elevated friction from lubrication failure or overload | Housing 15-25 C above symmetrical bearing or above ambient baseline |
| Coupling | Misalignment-induced friction, worn coupling elements | Coupling outer surface elevated versus adjacent bearing housings |
| Belt drive | Over-tension, misalignment, slipping | Sheave surface elevated; belt surface may show temperature variation along its length |
| Motor casing | Winding overload, cooling restriction, blocked ventilation | Casing temperature rise proportional to thermal load; compare to nameplate ambient limit |
| Gearbox housing | Internal bearing degradation, lubricant overheating | Localized hot spots over bearing locations; overall elevated case temperature |
The table represents typical patterns. Individual machines may have different baseline temperatures due to design, load profile, or ambient conditions. Establishing a baseline for each machine under known-good conditions is the foundation for reliable fault detection.
Thermographic Survey Procedure
A thermographic survey that produces repeatable, comparable data requires consistent conditions and procedure. Deviating from these conditions makes survey-to-survey comparison unreliable.
Operating Conditions Before the Survey
The machine must be at normal operating temperature before imaging. This typically means 30-60 minutes of operation at representative load. Surveying at startup captures startup transients, not steady-state fault signatures. Surveying at idle misses load-dependent heat sources entirely.
Imaging Protocol
- Image each asset from the same angle and approximately the same distance on each survey. Distance affects spatial resolution; angle affects emissivity and reflected radiation.
- Record ambient temperature with each image set. A machine that runs at 45 C surface temperature in a 20 C room and a 35 C room presents very differently in absolute terms but identically in delta-T terms.
- Record load conditions at the time of the survey. A motor at 30% load and 90% load will have meaningfully different thermal signatures; comparison is only valid at similar loads.
- Note any recent maintenance that may have changed surface condition, insulation, or lubrication state.
Comparison Reference
Where possible, compare each image against a reference image from a previous survey of the same machine under the same conditions. The delta between the current and reference image is more informative than the absolute temperature values alone.
Temperature Difference Analysis vs Absolute Temperature
For most mechanical monitoring applications, the temperature differential (delta-T) relative to a reference is more useful than the absolute surface temperature. Absolute temperature tells you the surface is at 62 C. Delta-T tells you it is 18 C hotter than its symmetrical counterpart, or 22 C hotter than last month's survey.
Useful comparison references:
- Symmetrical comparison: Bearing A versus bearing B on the same shaft, operating under the same load. A significant asymmetry indicates a localized problem on the hotter side.
- Time comparison: The current survey versus the last survey for the same bearing at the same operating conditions. A rising trend is more diagnostic than a single high value.
- Position comparison: One end of a motor versus the other end. Drive-end bearings typically run warmer than non-drive-end due to radial load, but the difference should be consistent and predictable.
A single hot bearing housing may be normal for that machine type and load condition. The same housing running 20 C hotter than last month's baseline, with load unchanged, is anomalous and warrants investigation. Trending over time converts thermography from a snapshot inspection into a condition monitoring tool.
Thermography for Electrical Equipment
Electrical panels, switchgear, and motor control centers are high-value thermographic inspection targets. Loose or corroded connections produce I²R heating that is directly visible in a thermal image.
Load requirement is critical for electrical surveys. At low load, even significantly degraded connections produce insufficient heat differential to identify the problem. The survey should be conducted when the circuit is carrying above 40% of its rated current. Below this threshold, a defective connection may read within a few degrees of its counterparts and be missed entirely.
The standard comparison for electrical work is phase-to-phase: three phases at similar load should produce similar temperatures at their connections, breakers, and bus bars. A single phase running significantly hotter than the other two identifies the fault location. This comparison method is inherent to three-phase systems and makes electrical thermography straightforward to interpret.
NEMA standards and NFPA 70B both reference thermographic inspection as part of electrical maintenance programs. Many insurance carriers and reliability programs specify thermographic surveys on an annual or biannual basis for critical electrical equipment.
Limitations
Thermography cannot see through solid objects. A hot bearing inside a closed housing is visible only through the heat it conducts to the outer surface. The surface temperature rise depends on the housing's thermal conductivity, mass, and ambient cooling: a heavy cast iron housing may show less than 5 C surface rise even when the internal bearing temperature has increased significantly. For enclosed equipment, thermography is a supplementary technique rather than a primary diagnostic tool.
Surface condition directly affects emissivity. Highly reflective surfaces require emissivity correction as described above. Surfaces with variable finish (rust patches, areas of fresh paint, oily sections) can show false temperature variation that does not correspond to actual temperature differences. Cleaning and standardizing the survey surface helps, but some surfaces are inherently difficult to measure accurately without contact reference.
Thermography identifies where heat is present. It does not directly identify the cause. A hot bearing housing could indicate lubrication failure, overloading, misalignment, a damaged race, or simply a change in ambient conditions. The thermal image directs attention to the right location; the root cause determination requires additional investigation, typically vibration analysis, oil analysis, or physical inspection.
Wind and ambient convection can cool surfaces unevenly and create apparent temperature variation that is not fault-related. Outdoor surveys or surveys near air handling equipment require careful interpretation. Enclosures and shields that alter the machine's normal cooling path will change baseline temperatures and require updated references.